Smooth-surface one-piece implants with an aggressive thread for immediate placement in extraction sockets and hard bone (D1–D2); Ø2.7 to Ø9.0, 8 to 35 mm.
Variants and codes
- Brand
- Monoimplant — One-piece implant system
- Family
- Smooth
- Type
- One-piece dental implants — smooth surface
- Category
- Implants
- Diameters
- Ø2.7 · 3.5 · 4.0 · 4.5 · 5.5 · 7.0 · 9.0 mm
- Lengths
- 8 – 35 mm
- Indication
- immediate placement; D1 – D2 bone
Characteristics

- 01
Smooth surface
No place for bacterial colonisation; better oral hygiene where bone resorption is likely after surgery.
- 02
Sharp self-tapping thread
Slices the bone instead of compressing it; cortical engagement at crest and apex.
- 03
Two abutment sizes
Normal and large abutment; trimming for prosthetic ease.
- 04
One-piece body
No abutment screw: no screw loosening, fracture or micro-movement at an implant–abutment interface.
- 05
Bicortical anchorage
Fixated between entry and exit cortical plates for primary stability that does not depend on trabecular bone.
- 06
Titanium grade 5
Biocompatible grade 5 titanium; abutments can be trimmed and are compatible with welding (syncrystallization).
Codes

| Length | Ø2.7 | Ø3.5 | Ø4.0 | Ø4.5 | Ø5.5 | Ø7.0 | Ø9.0 |
|---|---|---|---|---|---|---|---|
| 8 mm | — | — | — | MS4508 | MS5508 | MS7008 | MS9008 |
| 10 mm | MS2710 | MS3510 | MS4010 | MS4510 | MS5510 | MS7010 | MS9010 |
| 12 mm | MS2712 | MS3512 | MS4012 | MS4512 | MS5512 | MS7012 | MS9012 |
| 14 mm | MS2714 | MS3514 | MS4014 | MS4514 | MS5514 | MS7014 | MS9014 |
| 17 mm | MS2717 | MS3517 | MS4017 | MS4517 | MS5517 | — | — |
| 20 mm | MS2720 | MS3520 | MS4020 | MS4520 | MS5520 | — | — |
| 23 mm | MS2723 | MS3523 | MS4023 | MS4523 | MS5523 | — | — |
| 26 mm | MS2726 | MS3526 | MS4026 | MS4526 | — | — | — |
| 29 mm | MS2729 | MS3529 | MS4029 | MS4529 | — | — | — |
| 32 mm | — | MS3532 | MS4032 | — | — | — | — |
| 35 mm | — | MS3535 | MS4035 | — | — | — | — |
Large-abutment versions carry the suffix -LAb (Ø3.5 to Ø9.0). Ø2.7 is not intended as a single implant; in a thin jawbone at least 12 implants per jaw are required (catalogue).

Prosthetic head
The abutment is part of the implant body (normal or large). Impressions use the MIC transfer, burn-out cap and lab analog (MIC-LAb for the large abutment); scan body MSB / MSB-LAb and digital analog MDLA / MDLA-LAb for the digital workflow.
Documented compatibility
Only combinations stated in the product documentation are listed here; related products of the same brand are not assumed to be compatible.
- Impression components MIC / MIC-LAb →Transfer, burn-out cap and lab analog for the normal and large abutment (folding brochure Rev05).
- Monoimplant surgical kit →Drivers, lance drills and handles for all diameters (folding brochure).